Full Automatic Freezing Point Osmometer/Osmotic Pressure Gauge

Product Name: Osmometer
Warranty: Warranty
Measurement Range: 0~3000 Mosmol
Sample Amount: 100μl
Testing Duration: ≤3min
Pre-Cooling Time: ≤3min
Customization:
Manufacturer/Factory & Trading Company
Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Hunan, China
to see all verified strength labels (15)

Basic Info.

Model NO.
FPOSM-V2.0
Measurement Error
≤1%
Power Supply
220V~ 50Hz 150va
Transport Package
Standard Export Package
Trademark
Labkits
Origin
Hunan China
Production Capacity
500PCS/Month

Product Description

Item: Full Automatic Freezing Point Osmometer/Osmotic pressure gauge
Model: FPOSM-V2.0
Full Automatic Freezing Point Osmometer/Osmotic Pressure Gauge

Detailed introduction: 
The freezing point osmometer FPOSM-V2.0 produced by our company with independent research and development is in accordance with Raoul freezing point theory, based on the solution freezing point declined value proportional to the solution molar concentration, using high sensitivity of temperature-sensing element, to measure the freezing point of different solutions, so as to derive the osmotic pressure molar concentration. This theory has been widely used for the test and research of osmotic pressure molar concentration in the fields such as pharmaceuticals,pharmaceutical analysis, biological and food therapy

Features
1. It has the functions of electronic signature and user classification management, to satisfy CFR PART21 store data query according to time which can store 3 years of testing data.
2. It can carry on single-point or multi-point (31-point) linear calibration, to ensure that the instrument has the detection accuracy of each range interval in stability.
3. Instrument adopts the screw linear guide motor design, so that the operation just on a touch screen can complete the whole test process.
4. Temperature probe  adopts double refrigeration system, with a short pre-cooling time, fast detection speed,to facilitate continuous detection.
5. It can simultaneously display the osmotic pressure molar concentration value, the freezing point value and the molar concentration ratio.
6. The cooling system adopts the athermal transfer fluid design, to exempt from frequent maintenance.
7. Built-in "Chinese pharmacopoeia" hundreds of injectable drug name can facilitate the preset information of test sample.

Technical parameters

 
Measurement range 0~3000 mOsmol
Sample amount 100μl
Testing duration ≤3min
Pre-cooling time ≤3min
Measurement error ≤1%
Repeatability ≤1%
Linearity ≤1%
Environment temperature 0~30ºC  Recommended for 15~25ºC
Environment temperature ≤60%
Power supply 220V~ 50Hz 150VA
Dimensions 225mm*275mm*345mm
Weight 15kg
Resolution ratio 0.1