Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item: Distillate Fuel Oil Oxidation Stability Tester
Model: PT-SYD-0175
This instrument is designed and manufactured in accordance with the requirements of SH/T 0175, an industry standard of the People's Republic of China, for the determination of oxidation stability of distillate fuel oil (accelerated method). It is suitable for the determination of intrinsic stability of intermediate distillate fuel oil by accelerated oxidation method according to SH/T 0175 standard. It is the preferred automatic instrument for testing oxidation stability of distillate fuel oil by units of oil exploitation, production and use, relevant universities and scientific research departments.
Main Technical Characteristics:
1. The instrument has a floor-mounted structure and stainless-steel working table. It is reasonable in design, convenient in use and complete in matching.
2. The instrument adopts metal bath structure. It is clean, pollution-free, environment-friendly and energy-saving without adding water during the test.
3. The instrument has six test baths and six flowmeters, which indicate the flow rate of gas into six oxidation pipes respectively. It can carry out six samples at the same time and has high efficiency.
4. The heating furnace is composed of heating electric furnace and silicon-controlled temperature regulating circuit. The heating rate can be continuously adjusted.
The greatest characteristic of this instrument is that it adopts metal bath structure to remove the influence of water bath and oil bath structure on the corrosion or pollution of the test device, and the instrument keeps dry and tidy all the time.
II. Main technical specifications
1. Power supply: AC 220 V±10%, 50 Hz
2. Power consumption: ≤1600W
3. Temperature control mode: Automatically controlled by digital temperature controller
4. Temperature control range: Ambient ~100ºC
5. Temperature control accuracy: ±0.2ºC
6. Temperature measuring component: Thermal resistance
7. Sample quantity: It can make determination for 6 pieces of samples at the same time
8. Dimensions: 700mm* 440mm* 1345mm (length* width * height, including dark box).
PT-SYD-0175 Distillate Fuel Oils Oxidation Stability Tester Accessories and Documents List
No. | Name | Unit | Qty | Memo |
1 | PT-SYD-0175 Distillate Fuel Oils Oxidation Stability Tester | Set | 1 | |
2 | Oxidation tube | Piece | 6 | |
3 | Condenser | Piece | 6 | |
4 | Oxygen pipe | Piece | 6 | |
5 | Glass thermometer (50ºC~100ºC,scale mark 0.1ºC) | Piece | 1 | |
6 | Bath cover | Piece | 6 | |
7 | Silicone tube (inner diameter φ6) (Between flowmeter and glass oxygen pipe-250mm/piece) |
Piece | 6 | |
8 | Silicone tube (inner diameter φ6) (Glass condenser in series, water inlet and outlet, cut the length to the real condition) |
Piece | 3 meters | |
9 | Steel bottle connecting pipe (Between oxygen bottle and instrument, with connector of bottle) | Meter | 4 meters | |
10 | Fuse (φ6×30, 10A) | Piece | 2 | |
11 | Operation manual | Piece | 1 | |
12 | Quality certificate | Piece | 1 | |
13 | Product warranty card | Piece | 1 |
No. | Name | Specification | Quantity | Memo |
1 | Methylbenzene | Analytical pure 500ml | 3 bottles | |
2 | Acetone | Analytical pure500ml | 3 bottles | |
3 | Methyl alcohol | Analytical pure 500ml | 3 bottles | |
4 | Oxygen | Purity≥99.5% | 1 bottle | With reducing valve |
5 | Isooctane | Purity≥99.75% 500ml | 3 bottles | |
6 | Distilled water | 3 grades | Some | Used to clean glass ware |
7 | Electric hot plate | 135ºC | 1 Set | |
8 | Filter | Filtration membrane (cellulose film) | 1Box (50 pieces) | |
9 | Drying oven | 80ºC/105ºC | 1 set | |
10 | Drying apparatus | Medium-sized | 1 set |
Notes:
1.The reagent and equipment for installing the instrument are supplied by end-users themselves.
2.The usage, management and saving of poisonous and harmful reagent, pls operate according to the relative principle.
3.PLS read the operation manual and industry standard before using the instrument.
Petroleum & Oil Analyzer Petroleum Testing Instruments
· Open Cup Flash Point Tester
· Flash & Fire Point Tester for Petroleum Products
· Closed Cup Flash Point Tester
· Engler Viscometer
· Water Content Tester
· Rotational Viscometer
· Kinematics Viscometer
· Distillation Tester
· Density Tester Rust and Corrosion Tester
· Sulphur Content Tester
· Acid and Alkali Tester
· Dropping Point Tester
· Demulsibility Characteristics Tester
· Ash Content Tester
· Aniline Point Tester
· Low Temperature Tester
· Residue Carbon Tester
· Existent Gum Tester
· Vapor Pressure Tester
· Petroleum Products Vapor Pressure Tester(Reid Methods)
· Bomb Calorimeter
· OCTANE & CETANE ANALYZER
· Lubricating Grease Steel Sieve Oil Separation Tester
Lubricating Oils Foaming Characteristics Tester
Naphthalene Crystallizing Point Tester
Petroleum Products Color Tester
Mechanical Impurity Tester (Weight method)
Crude Petroleum and Petroleum Products Salt Content Tester
Petroleum Wax Oil Content Tester
Automatic Interfacial Tension Tester
Automatic Multifunctional Degassing Oscillation Tester
Insulating Oil Breakdown Voltage Tester
Insulating Oil Volume Resistivity Tester
Liquid Petroleum Products Hydrocarbon Tester
Lubricating Oil Air Release Value Tester
Self-ignition Point Tester
Insulation oil proof pressure tester
Precision adsorption column cleanser
Fluorescent Indicator Absorption Apparatus
dean stark apparatus(water content)(single tube)
dean stark apparatus(water content)(double tube)
Petroleum Products and additives Mechanical impurities tester
Petroleum Products Saybolt color tester(Saybolt colorimetric method)
Engine coolant Foam characteristic tester (glassware Method )
Jet fuel Solid particulate pollutant tester
Apparatus for water separability of petroleum oils
apparatus for Rusting Characteristics of Oils
Lubricating Grease Pressure Oil Separating Tester
Cone and Needle Penetration for petroleum products
Oil Separation Apparatus for grease